P3012
2C4B - P3012Information saved in
DME
Fault code
2C4B - P3012
Fault text
Control module, internal fault: oxygen sensor module
Fault description
O2 Sensor Signal Circuit Adaptation Value Too High (Bank
1 Sensor 1)
Condition for fault identification
Test condition:
Monitor for voltage adaptation value electr. calibration of
CJ125 IC
Calibration runs after engine start and in idle phases
Terminal condition: Terminal 15 ON
Voltage condition:
battery voltage<11V oder Ubatt > 16 volts
Condition for fault memory entry
Fault criterion:
Calibration adaptation value > 0.1 volts
Fault entry after 10 sec.
Action in service
1. Check wiring harness
2. Replace control module
Fault effect and breakdown warning
Driver information
Warning light:
MIL on (in 2nd driving cycle);
Service instruction
none