P2254
2C54 - P2254Information saved in
DME
Fault code
2C54 - P2254
Fault text
Oxygen sensor before catalytic converter 2, virtual ground
Fault description
O2 Sensor Negative Current Control Circuit/Open (Bank 2
Sensor 1)
Condition for fault identification
Test condition:
Monitoring for disconnected virtual ground wire (VM);
Diagnosis conditions:
- Overrun cutoff not active
- O2 sensor voltage is in 1.5 V range f. open wire
- No other faults are present for the LSU O2 sensor
- Fault detected through measured high internal resistance
(rinlsu2_w>1800 ohms)
Terminal condition: Engine running
Voltage condition:
battery voltage<11V oder Ubatt > 16 volts
Condition for fault memory entry
Fault monitoring criterion must remain present over 5 sec.
Action in service
Check plug / wiring harness / O2 wiring, otherwise replace
O2 sensor
Fault effect and breakdown warning
Driver information
Warning light:
MIL on (in 2nd driving cycle);
Service instruction
none