P2192
29E5 - P2192Information saved in
DME
Fault code
29E5 - P2192
Fault text
Fuel mixture adaptation, upper engine speed range
Fault description
System Too Rich at Higher Load (Bank 1)
Condition for fault identification
Test condition:
Fuel-supply system monitored with aid of mixture
adaptation data; here upper part-load range (multiplicative
adaptation), system too rich
Release conditions:
- No active EVAP air discharge
- No faults that disable diagnosis are present
- Relative charge (load) > 55 %
- Mass airflow > 250 kg/h
- Compliance with temperature conditions
Terminal condition: Engine running
Voltage condition:
battery voltage < 11 volts or battery voltage > 16 volts
Condition for fault memory entry
Approximately 10 min.
Action in service
High fuel pressure
Check positive crankcase ventilation
Check HFM (contamination, defective)
Check oxygen sensors before cat.
Fault effect and breakdown warning
Driver information
Warning light:
ECE MIL on (2nd cycle)
Service instruction
none