P2138
2D1B - P2138Information saved in
DME
Fault code
2D1B - P2138
Fault text
Accelerator pedal module, pedal-position sensor, signal 1
Fault description
Throttle/Pedal Position Sensor/Switch 'D' / 'E' Voltage
Correlation
Condition for fault identification
Test condition:
Implausible relationship between voltages for pedal-position
sensors 1 and 2
Terminal condition: Terminal 15=TRUE
Voltage condition:
battery voltage>7 V
Condition for fault memory entry
0.2 sec
Action in service
Check whether ADC test data in test data block upwg1_w
=2* upwg2_w. Maximum approved difference is 0.47 V.
Check wiring harness, test data, replace accelerator pedal,
test data, replace DME
Fault effect and breakdown warning
Driver information
Warning light:
EPCL
Service instruction
none