P2094
2A86 - P2094Information saved in
DME
Fault code
2A86 - P2094
Fault text
Exhaust VANOS, activation 2
Fault description
'B' Camshaft Position Actuator Control Circuit Low (Bank
2)
Condition for fault identification
Test condition:
Driver circuit has detected short to ground
Terminal condition: Terminal 15=TRUE
Voltage condition:
9.51
Condition for fault memory entry
500 ms
Action in service
VANOS plug: Check voltage supply (Terminal 87), DME
connection, replace VANOS solenoid valve, then replace
DME if problem persists
Fault effect and breakdown warning
Driver information
Warning light:
US: MIL on in 2nd driving cycle
ECE: No MIL
VVT emergency default mode (full stroke) active
VANOS emergency default mode (specification: 120�)
active
Service instruction
none