P1897
5016 - P1897Information saved in
GS
Fault code
5016 - P1897
Fault text
Sensor supply voltage
Fault description
Supply Voltage Sensors High Input
Condition for fault identification
Test condition:
--
Terminal condition: Ignition ON
Voltage condition:
7 ... 16V
Condition for fault memory entry
Filter counter controlled by time or events
Action in service
Replace Mechatronic
Fault effect and breakdown warning
Driver information
Warning light:
E_gearshift: CC-ID420
M-gearshift: CC-ID420
E-gearshift: Electr. default mode 3rd gear fix
M-gearshift: Mech. emergency default mode
Service instruction
none