P1702
50DD - P1702Information saved in
GS
Fault code
50DD - P1702
Fault text
Activation of two substitute functions of same priority
Fault description
Combination Substitute Function
Condition for fault identification
Test condition:
--
Terminal condition: Ignition ON
Voltage condition:
7 ... 16V
Condition for fault memory entry
Filter counter controlled by time or events
Action in service
If fault is passive: Check additional fault code entries.
Examine environmental conditions. Clear fault memory and
conduct road test under monitored conditions. If fault code
is not entered, transmission is OK. If it appears in
combination with other errors, proceed to resolve these.
If multiple fault code entries are present: Replace
Mechatronic
Fault effect and breakdown warning
Driver information
Warning light:
E-gearshift: CC-ID170/173
M-gearshift: CC-ID420
E-gearshift: Mech. emergency default mode
M-gearshift: Electr. emergency default mode
Service instruction
none