P16A4
2E73 - P16A4Information saved in
DME
Fault code
2E73 - P16A4
Fault text
Control module, internal fault: knock sensor module
Fault description
Timeout Control Module Knock Sensor SPI-Bus
Condition for fault identification
Test condition:
RPM > 1520 rpm
Load factor > 25
Terminal condition: Engine running
Voltage condition:
9 - 15 V
Condition for fault memory entry
< 10 sec.
Action in service
Replace DME
Fault effect and breakdown warning
Driver information
Warning light:
MIL on
Service instruction
none