P1577
2F50 - P1577Information saved in
DME
Fault code
2F50 - P1577
Fault text
No message from instrument cluster
Fault description
Speed Indication Signal Instrument Pack
Condition for fault identification
Test condition:
No suspension of bus activity, no active DSC intervention,
brake pedal not depressed, accelerator not depressed
Terminal condition: 800 ms after Terminal 15
Voltage condition:
battery voltage >10 V
Condition for fault memory entry
0.5 sec
Action in service
Check instrument cluster ECU
Check PT-CAN
Fault effect and breakdown warning
Driver information
Warning light:
FGR/ACC is deactivated
Service instruction
none