P1330
2E6A - P1330Information saved in
DME
Fault code
2E6A - P1330
Fault text
Knock-sensor signal 3
Fault description
Knock Sensor 3 Circuit High Input
Condition for fault identification
Test condition:
RPM > 1600 rpm
Load factor > 25
Terminal condition: Engine running
Voltage condition:
9 - 15 V
Condition for fault memory entry
< 3 sec.
Action in service
Check engine for mechanical defects, otherwise replace
sensor
Fault effect and breakdown warning
Driver information
Warning light:
MIL on
Service instruction
none