P113B
2D14 - P113BInformation saved in
DME
Fault code
2D14 - P113B
Fault text
Air mass sensor, correction signal
Fault description
Mass or Volume Air Flow 1 Correction Signal Plausibility
Period Too Short
Condition for fault identification
Test condition:
none
Terminal condition: Terminal 15 ON
Voltage condition:
Diagnosis active at battery voltage > 7.5 V
Condition for fault memory entry
1 sec.
Action in service
Check wiring harness, if OK replace HFM
Fault effect and breakdown warning
Driver information
Warning light:
MIL on (US model only)
Service instruction
none