P1054
2A68 - P1054Information saved in
DME
Fault code
2A68 - P1054
Fault text
Valvetronic, actuator motor 2: activation
Fault description
VVT-Control Circuit (Bank 2)
Condition for fault identification
Test condition:
- Fault class:
General trigger signal fault
Terminal condition: Terminal 15 ON
Voltage condition:
none
Condition for fault memory entry
3 ms
Action in service
Not reflected in TM
Fault effect and breakdown warning
Driver information
Warning light:
MIL (2nd driving cycle)
Service instruction
none