P1052
2A68 - P1052Information saved in
DME
Fault code
2A68 - P1052
Fault text
Valvetronic, actuator motor 2: activation
Fault description
VVT-Control Circuit Low Input (Bank 2)
Condition for fault identification
Test condition:
- Fault class:
Short to ground
Terminal condition: Terminal 15 ON
Voltage condition:
< 1.17 V
Condition for fault memory entry
3 ms
Action in service
Check wiring harness, otherwise replace servo motor
Fault effect and breakdown warning
Driver information
Warning light:
MIL (2nd driving cycle)
Service instruction
none