P1023
2A61 - P1023Information saved in
DME
Fault code
2A61 - P1023
Fault text
Valvetronic, adjustment range
Fault description
VVT-Self-Learning Function Faulty Adjustment Range
(Bank 1)
Condition for fault identification
Test condition:
- Fault class:
Adjustment range faulty
Terminal condition: Terminal 15 ON
Voltage condition:
>= 9 V
Condition for fault memory entry
100 ms
Action in service
Check balance spring installation; check mechanical
components for wear and stiction
Fault effect and breakdown warning
Driver information
Warning light:
none
Service instruction
none