P1014
2A5B - P1014Information saved in
DME
Fault code
2A5B - P1014
Fault text
Valvetronic, eccentric shaft sensor: reference
Fault description
VVT-Reference Sensor Parity Error (Bank 1)
Condition for fault identification
Test condition:
- Fault class:
Parity - fault or no signal
Terminal condition: DME, VVT - Active
Voltage condition:
none
Condition for fault memory entry
12 ms
Action in service
Check plug and wiring harness, hazard of sensor defect is
present with short to +12 V
Fault effect and breakdown warning
Driver information
Warning light:
none
Service instruction
none