P0132
2C47 - P0132Information saved in
DME
Fault code
2C47 - P0132
Fault text
Oxygen sensor before catalytic converter, sensor wires
Fault description
O2 Sensor Circuit High Voltage (Bank 1 Sensor 1)
Condition for fault identification
Test condition:
Detection of short to battery voltage in the O2 sensor wires:
Pump current Ip;
Calibration wire IA;
Ground VM;
Nernst voltage UN
Terminal condition: Engine running
Voltage condition:
battery voltage<11V oder Ubatt > 16 volts
Condition for fault memory entry
Fault monitoring criterion must remain present over 2 sec.
Action in service
Check plug / wiring harness / O2 sensor wiring, otherwise
replace DME
Fault effect and breakdown warning
Driver information
Warning light:
MIL on (in 2nd driving cycle);
Service instruction
none