P0015
2A88 - P0015Information saved in
DME
Fault code
2A88 - P0015
Fault text
VANOS exhaust
Fault description
'B' Camshaft Position - Timing Over-Retarded (Bank 1)
Condition for fault identification
Test condition:
Bank 1 exhaust controller monitor
(max. control deviation (differential spec./actual data) is
5�KW)
VANOS may not be at travel limit, that is
Vsa_sprs<120�KW.
Terminal condition: KL_15 = true
Voltage condition:
none
Condition for fault memory entry
Fault counter (Vnscnt) runs to 150. Duration roughly 7 sec.
at idle; about 1.5 sec. from 3000 rpm on
Action in service
Test sequence (after each step stop to determine whether
fault is present):
1. If the corresponding camshaft fault has been logged, start
by checking the camshaft sensor
2. Check oil level
3. Check VANOS valve for contamination
4. Replace solenoid valve
5. Replace VANOS adjustment mechanism
Fault effect and breakdown warning
Driver information
Warning light:
US: Standard OBD fault; MIL on after 2 driving cycles,
transmits to scan tool; no EPCL; delete fault after 40 warm-
up cycles
ECE: AS US but no MIL
Service instruction
none