P0010
2A80 - P0010Information saved in
DME
Fault code
2A80 - P0010
Fault text
Intake VANOS, activation
Fault description
'A' Camshaft Position - Actuator Circuit/Open (Bank 1)
Condition for fault identification
Test condition:
Driver circuit has detected open wire
Terminal condition: Terminal 15=TRUE
Voltage condition:
9.51
Condition for fault memory entry
500 ms
Action in service
VANOS plug: Check voltage supply (Terminal 87), DME
connection, replace VANOS solenoid valve, then replace
DME if problem persists
Fault effect and breakdown warning
Driver information
Warning light:
US: MIL on in 2nd driving cycle
ECE: No MIL
VVT emergency default mode (full stroke) active
VANOS emergency default mode (specification: 120�)
active
Service instruction
none