4FB1
4FB1 - P1791Information saved in
GS
Fault code
4FB1 - P1791
Fault text
Transmission control: Internal fault (EEPROM)
Fault description
Internal Transmission Control Module Memory Check
Sum/EEPROM Error
Condition for fault identification
Test condition:
--
Terminal condition: Ignition ON
Voltage condition:
11 ... 16V
Condition for fault memory entry
Filter counter controlled by time or events
Action in service
Replace Mechatronic
Fault effect and breakdown warning
Driver information
Warning light:
No driver report
No NP
Service instruction
none