4E26
4E26 - P1830Information saved in
GS
Fault code
4E26 - P1830
Fault text
Current fault, electronic pressure actuator in P/R/N
Fault description
Pressure Control Solenoid Current Error in P/R/N
Condition for fault identification
Test condition:
Position control for P, R or D
Terminal condition: Ignition ON
Voltage condition:
7 ... 16V
Condition for fault memory entry
Filter counter controlled by time or events
Action in service
1. Read out error frequency counter. If fault frequency is > 2
Replace Mechatronic.
2. If fault is passive: Clear fault memory and conduct road
test under monitored conditions. If fault code is not
registered, transmission OK
If fault code is entered repeatedly Replace Mechatronic
Fault effect and breakdown warning
Driver information
Warning light:
E-gearshift: CC-ID170
Electrical neutral
Service instruction
none