2F80 - P1515 (DME)
2F80 - P1515Information saved in
DME
Fault code
2F80 - P1515
Fault text
System time, plausibility
Fault description
Engine Off Timer Plausibility
Condition for fault identification
Test condition:
Implausible instrument cluster and/or power module signal
Terminal condition: Terminal 30
Voltage condition:
DME operating range 6 V - 16 V
Condition for fault memory entry
Time
Action in service
E65 : Check power module if no other CAN faults are
detected
E60 : Check instrument cluster if no other CAN faults are
detected
Fault effect and breakdown warning
Driver information
Warning light:
MIL
Service instruction
none