2F59
2F59 - P1650Information saved in
DME
Fault code
2F59 - P1650
Fault text
Automatic start, start signal
Fault description
Start While Engine is Running
Condition for fault identification
Test condition:
E65 only
Engine speed > 1200 rpm
Terminal condition: Terminal 15=TRUE
Voltage condition:
none
Condition for fault memory entry
none
Action in service
Check E_S_START wire; check starter and starter relay;
inspect CAS-SG
Fault effect and breakdown warning
Driver information
Warning light:
No CC
Service instruction
none