2F45 - P1661 (DME)
2F45 - P1661Information saved in
DME
Fault code
2F45 - P1661
Fault text
Interface EWS-DME
Fault description
Timeout EWS (Electronic Immobilizer)-Telegram
Condition for fault identification
Test condition:
Starting at T15 ON
Terminal condition: Terminal 15
Voltage condition:
none
Condition for fault memory entry
none
Action in service
Check D_EWS wire; measure with oscilloscope to see if
digital signal present at DME
Trigger CAS with tester, no response from CAS: Continue
problem diagnosis with CAS
Fault effect and breakdown warning
Driver information
Warning light:
none
Service instruction