2F44 - P1667 (DME)
2F44 - P1667Information saved in
DME
Fault code
2F44 - P1667
Fault text
EWS preventing manipulation
Fault description
EWS (Electronic Immobilizer) Start Value not yet
Programmed
Condition for fault identification
Test condition:
Starting at T15 ON
Terminal condition: Terminal 15
Voltage condition:
none
Condition for fault memory entry
none
Action in service
First, program start value; => Status feedback after start
value calibration has priority over FS
Fault effect and breakdown warning
Driver information
Warning light:
none
Service instruction
none