2EFE - P0692 (DME)
2EFE - P0692Information saved in
DME
Fault code
2EFE - P0692
Fault text
Electric fan, activation
Fault description
Fan 1 Control Circuit High
Condition for fault identification
Test condition:
Current at Pin 4-04 I > 1.1 A
Terminal condition: Terminal 15=TRUE
Voltage condition:
9.5 V < U < 17.9 V
Condition for fault memory entry
n> 40 rpm
Action in service
Check/replace components and wiring
Fault effect and breakdown warning
Driver information
Warning light:
none
Service instruction
none