2EBE
2EBE - U1133Information saved in
DME
Fault code
2EBE - U1133
Fault text
No BSD message from generator 2
Fault description
Lost Communication With Generator 2 via BSD (Bit Serial
Data Interface)
Condition for fault identification
Test condition:
2. Alternator installed (E67 only)
Terminal condition: Terminal 15
Voltage condition:
none
Condition for fault memory entry
4 sec.
Action in service
Check plug on alternator 2
Inspect BSD wire
Replace defective components as indicated
Fault effect and breakdown warning
Driver information
Warning light:
none
Service instruction
none