2DEC - P160A (DME)
2DEC - P160AInformation saved in
DME
Fault code
2DEC - P160A
Fault text
Power management, battery
Fault description
Powermanagement Exhaustive Discharge
Condition for fault identification
Test condition:
Battery deep discharge, battery voltage low, as measured by
IBS below 9.5 volts for min. 10 sec.
Terminal condition: Terminal 30
Voltage condition:
DME operating range
Condition for fault memory entry
none
Action in service
Check standby current draw, check and recharge battery
Fault effect and breakdown warning
Driver information
Warning light:
No warning lamp or CC status report
Service instruction
none