2DEC - P160A (DME)

2DEC - P160A

Information saved in
DME

Fault code
2DEC - P160A

Fault text
Power management, battery

Fault description
Powermanagement Exhaustive Discharge

Condition for fault identification
Test condition:
Battery deep discharge, battery voltage low, as measured by
IBS below 9.5 volts for min. 10 sec.
Terminal condition: Terminal 30
Voltage condition:
DME operating range

Condition for fault memory entry
none

Action in service
Check standby current draw, check and recharge battery

Fault effect and breakdown warning


Driver information
Warning light:
No warning lamp or CC status report

Service instruction
none