2DEB - P160C (DME)
2DEB - P160CInformation saved in
DME
Fault code
2DEB - P160C
Fault text
Power management, vehicle electrical system
Fault description
Powermanagement Overvoltage
Condition for fault identification
Test condition:
Below battery voltage measured by IBS, below 16 volts for
at least 10 sec.
Terminal condition: Terminal 15 with engine running
Voltage condition:
DME operating range
Condition for fault memory entry
none
Action in service
Has vehicle been jump-started? Fault counter =1 and fault
not currently present, then delete stored fault codes from
log.
Otherwise check electrical system voltage, if voltage >16V
replace alternator
Fault effect and breakdown warning
Driver information
Warning light:
No warning lamp or CC status report
Service instruction
none