FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

2DEB - P160C (DME)

2DEB - P160C

Information saved in
DME

Fault code
2DEB - P160C

Fault text
Power management, vehicle electrical system

Fault description
Powermanagement Overvoltage

Condition for fault identification
Test condition:
Below battery voltage measured by IBS, below 16 volts for
at least 10 sec.
Terminal condition: Terminal 15 with engine running
Voltage condition:
DME operating range

Condition for fault memory entry
none

Action in service
Has vehicle been jump-started? Fault counter =1 and fault
not currently present, then delete stored fault codes from
log.
Otherwise check electrical system voltage, if voltage >16V
replace alternator

Fault effect and breakdown warning


Driver information
Warning light:
No warning lamp or CC status report

Service instruction
none