2D71 - P3237 (DME)
2D71 - P3237Information saved in
DME
Fault code
2D71 - P3237
Fault text
Control module, internal fault: monitoring of input variables
Fault description
Control Module Monitoring Fuel Correction Error
Condition for fault identification
Test condition:
Torque monitor
Terminal condition: nmot > 1200 rpm
Voltage condition:
none
Condition for fault memory entry
none
Action in service
If additional fault codes are entered in the DME, resolve
these issues. If fault still remains current, replace DME.
Fault effect and breakdown warning
Driver information
Warning light:
Fuel-supply safety shutdown
Service instruction
none