2D0F - P0102 (DME)
2D0F - P0102Information saved in
DME
Fault code
2D0F - P0102
Fault text
Air-mass sensor, signal
Fault description
Mass or Volume Air Flow 'A' Circuit Low
Condition for fault identification
Test condition:
none
Terminal condition: Terminal 15 ON
Voltage condition:
Diagnosis active at battery voltage > 7.5 V
Condition for fault memory entry
0.2 sec.
Action in service
Check wiring harness, if OK replace HFM
Fault effect and breakdown warning
Driver information
Warning light:
MIL on
Service instruction
none