2C4E - P3021 (DME)
2C4E - P3021Information saved in
DME
Fault code
2C4E - P3021
Fault text
Oxygen sensor before catalytic converter 2, pump current
cable
Fault description
O2 Sensor Signal Voltage Too Low during Coast Down
Fuel Cut-Off due to Open Pumping Current Circuit (Bank 2
Sensor 1)
Condition for fault identification
Test condition:
Monitoring on disconnected pump current wire (IP);
Diagnosis conditions:
- Overrun cutoff present for at least 3 min.
- Voltage on CJ125 < 1.7 V
- Sensor heated adequately
Terminal condition: Engine running
Voltage condition:
battery voltage<11V oder Ubatt > 16 volts
Condition for fault memory entry
Fault monitoring criterion must remain present over 2 sec.
Action in service
Check plugs/wiring harness, otherwise replace sensor
Fault effect and breakdown warning
Driver information
Warning light:
MIL on (in 2nd driving cycle);
Service instruction
none