2BC1 - P110F (DME)
2BC1 - P110FInformation saved in
DME
Fault code
2BC1 - P110F
Fault text
Ambient temperature sensor, signal
Fault description
Ambient Air Temperature Sensor Faulty CAN Signal
Condition for fault identification
Test condition:
Ambient temperature from instrument cluster invalid
Terminal condition: Terminal 15=TRUE
Voltage condition:
none
Condition for fault memory entry
none
Action in service
Check plug /wiring harness at instrument cluster, otherwise
replace ambient temperature sensor
Fault effect and breakdown warning
Driver information
Warning light:
ECE: none
US: MIL on in 2nd DC
Service instruction
none