Condition For Fault ID - 1
2BC0 - P0071Information saved in
DME
Fault code
2BC0 - P0071
Fault text
Ambient temperature sensor, plausibility
Fault description
Ambient Air Temperature Sensor Range/Performance
Condition for fault identification
Test condition:
Ambient temperature 20� above model figure
Terminal condition: Engine running, vehicle velocity >40
km/h
Voltage condition:
none
Condition for fault memory entry
4 sec.
Action in service
Check plug /wiring harness at instrument cluster, otherwise
replace ambient temperature sensor
Fault effect and breakdown warning
Driver information
Warning light:
ECE: none
US: MIL on in 2nd DC
Service instruction
none