2B9C
2B9C - P0606Information saved in
DME
Fault code
2B9C - P0606
Fault text
Control module, internal fault: reset
Fault description
ECM/PCM Processor
Condition for fault identification
Test condition:
DME selftest
Terminal condition: none
Voltage condition:
none
Condition for fault memory entry
none
Action in service
Replace DME
Fault effect and breakdown warning
Driver information
Warning light:
EPCL + various warning lamps from other ECUs, as DME
is not transmitting messages to the bus
Service instruction
none