2B82 - P1562 (DME)
2B82 - P1562Information saved in
DME
Fault code
2B82 - P1562
Fault text
not translated
Fault description
Cold Start Idle Air Control System RPM Higher Than
Expected (Bank 1)
Condition for fault identification
Test condition:
Idle speed deviation during catalyst heating (400 rpm above
upper limit)
Terminal condition: Engine after starting with catalyst
heating
Voltage condition:
none
Condition for fault memory entry
8 sec.
Action in service
Replace DVE only if no LR adaptation fault has been
entered (vacuum leak)
Fault effect and breakdown warning
Driver information
Warning light:
none
Service instruction
none