FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

2A8D

2A8D - P0024

Information saved in
DME

Fault code
2A8D - P0024

Fault text
Exhaust VANOS, adaptation stop 2

Fault description
'B' Camshaft Position - Timing Over-Advanced or System
Performance (Bank 2)

Condition for fault identification
Test condition:
Bank 2 exhaust travel-limit adaptation monitor
(if OK: 58�KW < Vsa2_adp < 84�KW)
VANOS must be at travel limit, i.e., Vsa2_sprs=120�KW.
Terminal condition: KL_15 = true
Voltage condition:
none

Condition for fault memory entry
Entered immediately

Action in service
Test sequence (check to determine whether fault is still
present after each step):
1. If corresponding camshaft sensor fault has been logged,
start by checking camshaft sensor
2. Check VANOS valve for contamination
3. Check reluctor position
4. Check chain length and tension

Fault effect and breakdown warning


Driver information
Warning light:
US: Standard OBD fault; MIL on after 2 driving cycles,
transmits to scan tool; no EPCL; delete fault after 40 warm-
up cycles
ECE: AS US but no MIL

Service instruction
none