2A8A
2A8A - P0011Information saved in
DME
Fault code
2A8A - P0011
Fault text
Inlet VANOS, adaptation stop
Fault description
'A' Camshaft Position - Timing Over-Advanced or System
Performance (Bank 1)
Condition for fault identification
Test condition:
Bank 1 intake travel-limit adaptation monitor
(if OK: 115�KW < Vsa2_adp < 141�KW)
VANOS must be at travel limit, i.e., Vsa_sprs=120�KW.
Terminal condition: KL_15 = true
Voltage condition:
none
Condition for fault memory entry
Entered immediately
Action in service
Test sequence (check to determine whether fault is still
present after each step):
1. If corresponding camshaft sensor fault has been logged,
start by checking camshaft sensor
2. Check VANOS valve for contamination
3. Check reluctor position
4. Check chain length and tension
Fault effect and breakdown warning
Driver information
Warning light:
US: Standard OBD fault; MIL on after 2 driving cycles,
transmits to scan tool; no EPCL; delete fault after 40 warm-
up cycles
ECE: AS US but no MIL
Service instruction
none