FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

2A6E - P1082 (DME)

2A6E - P1082

Information saved in
DME

Fault code
2A6E - P1082

Fault text
Valvetronic, electric overload protection 2

Fault description
VVT-Overload Protection Control Motor Current High
Input (Bank 2)

Condition for fault identification
Test condition:
- Fault class:
E motor activation current
too high
Terminal condition: Terminal 15 ON
Voltage condition:
none

Condition for fault memory entry
45 ms

Action in service
Checking resistance between winding and casing is not
possible with available test technology; check magnets in
reluctor to determine if they have fallen out;
check reluctor installation;
check for wear and stiction in mechanical components

Fault effect and breakdown warning


Driver information
Warning light:
none

Service instruction
none