2A6E - P1082 (DME)
2A6E - P1082Information saved in
DME
Fault code
2A6E - P1082
Fault text
Valvetronic, electric overload protection 2
Fault description
VVT-Overload Protection Control Motor Current High
Input (Bank 2)
Condition for fault identification
Test condition:
- Fault class:
E motor activation current
too high
Terminal condition: Terminal 15 ON
Voltage condition:
none
Condition for fault memory entry
45 ms
Action in service
Checking resistance between winding and casing is not
possible with available test technology; check magnets in
reluctor to determine if they have fallen out;
check reluctor installation;
check for wear and stiction in mechanical components
Fault effect and breakdown warning
Driver information
Warning light:
none
Service instruction
none