FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

2A6E - P1080 (DME)

2A6E - P1080

Information saved in
DME

Fault code
2A6E - P1080

Fault text
Valvetronic, electric overload protection 2

Fault description
VVT-Overload Protection ECU-Temperature High Input
(Bank 2)

Condition for fault identification
Test condition:
- Fault class:
Control module temperature too high
Terminal condition: Terminal 15 ON
Voltage condition:
none

Condition for fault memory entry
45 ms

Action in service
Checking resistance between winding and casing not
possible with available test technology.
Check reluctor for missing magnets;
check reluctor installation;
check for mechanical wear and stiction

Fault effect and breakdown warning


Driver information
Warning light:
none

Service instruction
none