2A6C
2A6C - P1064Information saved in
DME
Fault code
2A6C - P1064
Fault text
Valvetronic, position at new start: plausibility
Fault description
VVT-Value Comparison Starting Position/Parking Position
Plausibility (Bank 1)
Condition for fault identification
Test condition:
- Fault class:
VVT data comparison
Deactivation position / Start position
(plausibility fault)
Terminal condition: Terminal 15 ON
Voltage condition:
none
Condition for fault memory entry
500 ms
Action in service
Terminal 15 off, wait until HR releases, Terminal 15 on,
VVT initializes automatically
Fault effect and breakdown warning
Driver information
Warning light:
none
Service instruction
none