2A6B - P1063 (DME)
2A6B - P1063Information saved in
DME
Fault code
2A6B - P1063
Fault text
Valvetronic, power limitation
Fault description
VVT-Limp Home Request Air Mass Plausibility (Bank 1)
Condition for fault identification
Test condition:
- Fault class:
Excentric overload angle detected
Fault (mass airflow -
plausibility fault)
Terminal condition: Terminal 15 ON
Voltage condition:
none
Condition for fault memory entry
4000 ms
Action in service
Resolve primary VVT fault
Fault effect and breakdown warning
Driver information
Warning light:
MIL (2nd driving cycle)
EML
Service instruction
none