2A19 - P0444 (DME)
2A19 - P0444Information saved in
DME
Fault code
2A19 - P0444
Fault text
Tank-venting valve, activation
Fault description
Evaporative Emission System Purge Control Valve Circuit
Open
Condition for fault identification
Test condition:
Current at Pin 3-21 I > 3.8 A
Terminal condition: Terminal 15=TRUE
Voltage condition:
9.5 V < U < 17.9 V
Condition for fault memory entry
n> 40 rpm, 2 % <= tateist_w <= 80 %
Action in service
Stecker / check wiring harness, otherwise replace DME
Fault effect and breakdown warning
Driver information
Warning light:
MIL ON in 2nd DC
Service instruction
none