29F0 - P2190 (DME)
29F0 - P2190Information saved in
DME
Fault code
29F0 - P2190
Fault text
Fuel mixture adaptation 2, sumcheck fault
Fault description
System Too Rich at Idle (Bank 2)
Condition for fault identification
Test condition:
Fuel-supply system monitored with aid of mixture
adaptation data; here idle range (additive adaptation), system
too rich
Release conditions:
- No active EVAP air discharge
- No faults that disable diagnosis are present
- Mass airflow < 34 kg/h
- Compliance with temperature conditions
Terminal condition: Engine running
Voltage condition:
battery voltage < 11 volts or battery voltage > 16 volts
Condition for fault memory entry
Approximately 10 min.
Action in service
Check fuel pressure (regulator, return line)
Check oxygen sensors before cat.
Check tank EVAP purge air discharge (air leak !)
Check HFM (contamination, defect)
Fault effect and breakdown warning
Driver information
Warning light:
US MIL on (2nd driving cycle)
Service instruction
none