Replacing Desiccant Insert For A / C System (Condenser Removed)
64 53 517 - Replacing desiccant insert for A / C system (condenser removed)
Remove cover cap (1) from condenser (2).
Press sealing cap (1) inwards and remove Seeger circlip ring (2).
With assistance of a screwed-in screw (1), remove sealing cap (2) from condenser (3).
Installation:
Replace sealing rings (1) of sealing cap (2) and coat with suitable refrigerant oil (cf. EPC).
Withdraw desiccant insert in direction of arrow from capacitor (2).