Opening of Passenger Front By Driver
Opening of Passenger Front by DriverThe signal triggered in the SBFA when the button is pressed is sent via a LIN Bus to the TMFA. The TMFA sends the signal via the byteflight to the SGM.
The SGM converts the signal and sends it on the K-CAN to the CAS(the master for the front windows). The CAS evaluates the signal and sends a command to the SGM on the K-CAN. The SGM forward the command via the byteflight to the TMBF.