Camshaft Position Sensor: Service and Repair
- Interrogate fault memory of DME control unit.- Switch off Ignition.
- Remove cover from injector valves.
- Disconnect plug connection for VANOS solenoid valve on electrical strip on injector valves.
- Unscrew solenoid.
Installation Note: Check gasket and replace if necessary.
Tightening Torque = 30 Nm.
- Unfasten hydraulic line on VANOS adjustment unit.
Tightening Torque = 32 Nm.
- Release screw on sensor.
Tightening Torque = 5.0 Nm.
Installation Note: Check gasket and replace if necessary.
- Disconnect plug-in connection(3). Plug connection illustrated here with intake manifold removed.
Installation Note: Interrogate fault memory of DME control unit, check faults in memory, rectify faults in memory, rectify faults and clear fault memory.