Sensor Heating Relay
Oxygen Sensor Heating Relay:Check function:
•D• 3 - Component Activation.
The relay remains switched on during normal operation until high engine speeds or loads occur.
Possible causes:
- Wire to DME control unit Pin 37 defective
- Relay or voltage supply not OK.
- Fuse defective