Without Heater Removed
- Disconnect battery ground lead.
- Pull off rubber strip.
- Unscrew bolts.
- Push back retaining tabs (3) and remove blower shells (1 and 2).
Installation:
Flat surfaces on inlet cowls face body.
- Pull off plug.
- Disconnect retaining strap.
- Remove motor with fan.
Installation:
• Positioning of blower motor is given by shape of housing.
• Check armature axial play.
Important!
Do not take fan off of motor shaft or turn on shaft, since motor was balanced with fan as an assembly.