With Heater Removed
- Push back retainers (3) and remove blower shells (1 and 2).
Installation:
Flat surface on inlet cowls faces body.
- Pull off plug.
- Disconnect retaining strap.
- Remove motor with fan.
Installation:
• Position of blower motor is given by shape of housing.
• Check code number.
• Check armature axial play.
Important! Do not remove fans on motor shaft or turn on shaft, since motor and fans have been balanced as an assembly.