Carbon Brush Checking, Valeo Generator, From 2007
Carbon Brush Checking, Valeo Generator, from 2007
Special tools, testers and auxiliary items required
• Feeler Gauge 0.3 mm
Procedure
- Remove voltage regulator. Refer to=> [ Voltage Regulator, Valeo Generator, from 2007 ] Voltage Regulator, Valeo Generator, From 2007.
- Insert a feeler gauge 0.3 mm - 3 - between protective cap - 2 - and the carbon brushes.
- Remove the protective cap from voltage regulator - 1 - - arrow -.
- Check carbon brushes for length - a -.
• Wear limit: - a - = 5 mm.
- With protective cap - 2 - installed, use feeler gauge - 4 - to press carbon brushes- 3 - down.
- Push the protective cap off - arrow - until the bar of the protective cap presses the carbon brushes down.
- Install the voltage regulator. Refer to=> [ Voltage Regulator, Valeo Generator, from 2007 ] Voltage Regulator, Valeo Generator, From 2007.